INSTALLATION SERIES
Australian Monitor
DigiPageJr
Multizone Paging
Program Selection
System
&
Clever Features, Contractor Friendly
Installation
Operation
Manual
&
ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 PAGE ENABLE
PROG 1 PROG 1 PROG 1 PROG 1 PROG 1 PROG 1 PROG 1 PROG 1
ZONE 1
ZONE 2
ZONE 3
ZONE 4
POWER
ON
ZONE 5
ZONE 6
ZONE 7
ZONE 8
PROG 2 PROG 2 PROG 2 PROG 2 PROG 2 PROG 2 PROG 2 PROG 2
PROG 3 PROG 3 PROG 3 PROG 3 PROG 3 PROG 3 PROG 3 PROG 3
PROG 4 PROG 4 PROG 4 PROG 4 PROG 4 PROG 4 PROG 4 PROG 4
MASTER 1 MASTER 2
MASTER 3
MASTER 4 MASTER 5 MASTER 6 MASTER 7 MASTER 8
TREBLE TREBLE TREBLE TREBLE TREBLE TREBLE TREBLE TREBLE
BASS BASS BASS BASS BASS BASS BASS BASS
PROG PROG PROG PROG PROG PROG PROG PROG
MIC MIC MIC MIC MIC MIC MIC MIC
55555555
44444444
33333333
22222222
11111111
00000000
10 10 10 10 10 10 10 10
99999999
88888888
77777777
66666666
INSTALLATION SERIES
Austr alian Monitor
Vedere la pagina 0
1 2 3 4 5 6 ... 23 24

Sommario

Pagina 1 - DigiPageJr

INSTALLATION SERIESAustralian MonitorDigiPageJrMultizone PagingProgram SelectionSystem&Clever Features, Contractor FriendlyInstallationOperationMa

Pagina 2 - WARNING !

5 PROG LINKS6 DATA LINK7 MASTER/SLAVE8 POWER IN VACThese RJ45 sockets allow linking of the program sources when using a Master/Slaveconfiguration. (se

Pagina 3 - CONTENTS

4. INSTALLATIONOVERVIEWNOTE: XLR CONFIGURATIONCABLE INSTALLATION FOR PAGING STATIONSCAT 5 RUN 1-4The DigiPageJr features extensive flexibility in the

Pagina 4 - 1. INTRODUCTION

INSTALLATION OF A PRIORITY PAGING STATIONCAT5 CABLECAT5 TERMINATIONPOWER REQUIREMENTSThe following rules apply for connecting a paging station as a pr

Pagina 5 - Expanded view

EXTENDING CAT5 CABLE RUN DISTANCES & ADDING MORE PAGING STATIONSTONE GENERATOR INPUTSPRE-ANNOUNCE CHIMEThe maximum distances quoted in the Table #

Pagina 6

5. SET UPThe inputs of the DigiPageJr can accommodate a wide range of sources including activepaging stations, dynamic microphones, DVD and CD players

Pagina 7

NOTE: A full discussion of setting up a complex system with correct gain structure isbeyond the scope of this manual. The procedure above assumes that

Pagina 8 - 3. BACK PANEL

6. LINKING TWO DIGIPAGEJr SYSTEMSDigiPageJr is fully expandable to form a 16 zone paging system by the simple linking of twounits. One DigiPageJr is t

Pagina 9

NOTE: If PROG LINKS is not used, it is possible to use completely different programsources in zones 1-8 to zones 9-16.NOTE: Maximum prog link cable le

Pagina 10 - Australian Monitor

1 ZONE select2. CLEAR3. ALL PAGE4. ZONE PAGE5. BUSYThese buttons allow selection of zones for paging.When selected, the adjacent LED glows green.Press

Pagina 11 - 4. INSTALLATION

DigiPageJrM16Installation and SetupThe CAT5 cable connects to the RJ45 socket on the rear panel of the paging station. Thissocket is a NEUTRIK connect

Pagina 12

CAUTIONRISK OF ELECTRIC SHOCKDO NOT OPENCAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK.DO NOT REMOVE COVER (OR BACK).NO USER-SERVICEABLE PARTS INSIDE.R

Pagina 13

208. ACCESSORIES8 zone Paging Station Cat No. DPJR8M16 Zone Paging Station Cat No. DPJR16MPunch down tool Cat No. DPPDTBlack System Input Plate Cat No

Pagina 14 - 5. SET UP

2110. BLOCK DIARGRAMINSTALLATION SERIESAustralian MonitorZONE OUPUT+6dBEQ0dBPROGRAMP1LINEMIC-43dB-43dB+30dB-33dB+13.5dBCAT5 RUN2-4DATA LINKSUM INPUTEV

Pagina 15

11. DIMENSIONSZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 PAGE ENABLEPROG 1 PROG 1 PROG 1 PROG 1 PROG 1 PROG 1 PROG 1 PROG 1ZONE 1ZONE 2ZO

Pagina 16 - Program Source Wiring

-Dimensions:-Weight:-Power Input:-88.0 x 482.0 x 205.5 (HxWxD) mmNet 4.5kg Shipping 5.5kgNet 9.9lb Shipping 12.1lb20VAC30VA maxProgram Sources:-Sum In

Pagina 17

Sydney(NSW & ACT Sales)Melbourne(Vic & Tas Sales)Brisbane(Qld Sales)Adelaide(SA & NT Sales)Perth(WA Sales)Auckland(NZ Sales)Private Bag 14

Pagina 18 - 7. PAGING STATION

CONTENTSPage1. Introduction 42. Front Panel 53. Back Panel 84. Installation 115. Setup 146. Linking Two DigiPageJr Systems 167. Paging Station 1810. B

Pagina 19 - DigiPageJrM16

1. INTRODUCTIONThe Australian Monitor Installation Series DigiPageJr is a two rack unit multizone paging andsource selection system that offers unprec

Pagina 20 - 9. TROUBLESHOOTING GUIDE

INSTALLATION SERIESAustralian Monitor12347 95682. FRONT PANELExpanded viewZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8PAGE ENABLEPROG 1 PRO

Pagina 21 - INSTALLATION SERIES

NOTE: Note that ‘center’ is to the right (3 o’clock), not the top (12 o’clock).NOTE: Note that ‘center’ is to the right (3 o’clock), not the top (12 o

Pagina 22

Located at the right-hand end of the unit, these controls affect all zones.7 PAGE ENABLE8ON9 POWERThis switch allows the zone to be included in or iso

Pagina 23 - 12 .SPECIFICATIONS

1 PROG 1 - 4 Input SectionLINEMICPROG GAINThe pair of RCA sockets accepts unbalanced line level inputs.Stereo signals are internally summed to mono.Th

Pagina 24 - USA/MEXICO/SOUTH AMERICA

3 EUROBLOCK CONNECTOR24V DC / GROUNDALERT/EVAC/COMMONGROUND/SUM INSUM INPUT LEVELTONE GEN OUTPUT LEVELThis input pair is for connection to a 24VDCemer